Review



smart lab x ray diffractometer  (Rigaku Corporation)


Bioz Verified Symbol Rigaku Corporation is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Rigaku Corporation smart lab x ray diffractometer
    Smart Lab X Ray Diffractometer, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 99/100, based on 45704 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/smart+lab+diffractometer/SmartLab/pm42882594-113-9-8
    Average 99 stars, based on 45704 article reviews
    smart lab x ray diffractometer - by Bioz Stars, 2026-11
    99/100 stars

    Images

    Related Articles

    X-ray Diffraction:

    Article Title: Amplified Turing Structures of Covalent Organic Frameworks for Ionic Nanofiltration under Extremely Low Pressures
    Article Snippet: Turing-structured covalent organic framework (COF) membranes featuring ordered nanopores and internal cavities are appealing for high-efficient ionic nanofiltration, while the efficient and controllable preparation remains challenging.. Herein, we report Turing-structured COF membranes with amplified inner cavities for fast and selective ion sieving.. A modulation layer is constructed that allows catalyst and water to transport from the inner pores to the reaction zone, triggering local activation via rapid COF formation.

    Article Title: Ecofriendly synthesis and characterization of copper chitosan nanoparticles (CuChNPs) and assessing combined effect of nanoparticles and bismerthiozol against bacterial leaf blight of rice
    Article Snippet: Surface plasmon resonance (SPR) of the nanoparticles was assessed via UV–visible spectroscopy (Shimadzu UV-2600i, Japan), measuring light absorption across wavelengths from 500 to 600 nm over time to determine their optical characteristics and peak absorption values . .. Powder X-ray diffraction (XRD) analysis was conducted using Cu Kα radiation (λ = 0.154 nm) on a Smart Lab diffractometer (Rigaku, Japan) operated at 40 kV and 50 mA. ..

    Article Title: Acid-responsive nanoparticles with microneedles for anti‑inflammatory sonodynamic therapy of gouty arthritis.
    Article Snippet: .. Crystallinity analysis: the crystalline states of the samples (5 mg each of Blank-PNPs, Cur-PNPs and Cur‐aggregates powder) were characterized by X-ray diffraction (XRD) on a Smart Lab diffractometer (Rigaku Corporation, Tokyo, Japan) operating at 40 kV and 40 mA with Cu Kα radiation (λ = 1.5406 Å). ..

    Article Title: Eggshell waste derived CaO as a tribocatalyst for removal of Rhodamine B dye under ambient light and sunlight.
    Article Snippet: Calcium oxide (CaO) was synthesized from waste chicken eggshells through calcination at 900 °C and examined to determine catalytic efficiency in degrading Rhodamine B (RhB) dye.. Although CaO exhibits photocatalytic properties, to enhance its catalytic performance, a tribocatalytic and solar-tribocatalytic approach was utilized for RhB dye degradation.. The material was characterized using X-ray diffraction, Raman spectroscopy, Photoluminescence, Diffuse reflectance spectrum, X-ray photoelectron spectroscopy and Scanning electron microscopy with energy-dispersive X-ray spectroscopy to analyze its structural and morphological properties.

    Article Title: Industrial-scale validation of lamellae thickness as a key structural descriptor for high-temperature and high-voltage performance of BOPP capacitor films
    Article Snippet: High-temperature and high-voltage stability are central challenges for biaxially oriented polypropylene (BOPP) capacitor films, yet the lab-to-industry translation of performance optimization remains limited.. Although intrinsic structure regulation is widely recognized as a production-compatible strategy, the relative contributions of different structure parameters to the performance remain unclear.. Herein, ton-scale BOPP films with distinct structural features were produced on an industrial biaxial stretching line by regulating the mechanical rate.

    Article Title: Synthesis of Cu-doped V 2 O 5 thin films with improved optical and CO 2 gas sensing
    Article Snippet: .. X-ray diffraction (XRD) patterns were recorded with a Smart Lab diffractometer (RIGAKU) using Cu Kα radiation ( λ = 0.1544 nm) over a 2 θ range of 10–80° with a step size of 0.02°, enabling phase identification and assessment of Cu incorporation into the V 2 O 5 lattice. ..

    Analysis:

    Article Title: Acid-responsive nanoparticles with microneedles for anti‑inflammatory sonodynamic therapy of gouty arthritis.
    Article Snippet: .. Crystallinity analysis: the crystalline states of the samples (5 mg each of Blank-PNPs, Cur-PNPs and Cur‐aggregates powder) were characterized by X-ray diffraction (XRD) on a Smart Lab diffractometer (Rigaku Corporation, Tokyo, Japan) operating at 40 kV and 40 mA with Cu Kα radiation (λ = 1.5406 Å). ..



    Similar Products

    99
    Rigaku Corporation smart lab x ray diffractometer
    Smart Lab X Ray Diffractometer, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/smart+lab+diffractometer/SmartLab/pm42882594-113-9-8
    Average 99 stars, based on 1 article reviews
    smart lab x ray diffractometer - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Rigaku Corporation smart lab diffractometer
    Smart Lab Diffractometer, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/smart+lab+diffractometer/SmartLab/pm42868112-125-25-28
    Average 99 stars, based on 1 article reviews
    smart lab diffractometer - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Rigaku Corporation smart lab se x ray diffractometer
    Smart Lab Se X Ray Diffractometer, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/smart+lab+diffractometer/SmartLab+SE/pm42840485-82-2-1
    Average 99 stars, based on 1 article reviews
    smart lab se x ray diffractometer - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Rigaku Corporation smart lab x ray powder diffractometer
    <t>X-ray</t> <t>diffraction</t> patterns of synthesized mackinawite.
    Smart Lab X Ray Powder Diffractometer, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/smart+lab+diffractometer/SmartLab/pmc13684076-100-15-14
    Average 99 stars, based on 1 article reviews
    smart lab x ray powder diffractometer - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Rigaku Corporation rigaku smart lab diffractometer
    <t>X-ray</t> <t>diffraction</t> patterns of synthesized mackinawite.
    Rigaku Smart Lab Diffractometer, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/smart+lab+diffractometer/SmartLab/pm42849270-62-16-16
    Average 99 stars, based on 1 article reviews
    rigaku smart lab diffractometer - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Rigaku Corporation smart lab 9kw x ray polycrystalline diffractometer
    <t>X-ray</t> <t>diffraction</t> patterns of synthesized mackinawite.
    Smart Lab 9kw X Ray Polycrystalline Diffractometer, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/smart+lab+diffractometer/SmartLab/10__3390_slash_coatings16101186-56-3-12
    Average 99 stars, based on 1 article reviews
    smart lab 9kw x ray polycrystalline diffractometer - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Rigaku Corporation smart lab se x ray diffractometer xrd
    <t>X-ray</t> <t>diffraction</t> patterns of synthesized mackinawite.
    Smart Lab Se X Ray Diffractometer Xrd, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/smart+lab+diffractometer/SmartLab+SE/10__1016_slash_j__jmatprotec__2026__119545-106-8-7
    Average 99 stars, based on 1 article reviews
    smart lab se x ray diffractometer xrd - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Rigaku Corporation smart lab sex ray diffractometer
    <t>X-ray</t> <t>diffraction</t> patterns of synthesized mackinawite.
    Smart Lab Sex Ray Diffractometer, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/smart+lab+diffractometer/SmartLab/pm41980530-50-11-10
    Average 99 stars, based on 1 article reviews
    smart lab sex ray diffractometer - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    Image Search Results


    X-ray diffraction patterns of synthesized mackinawite.

    Journal: Frontiers in Microbiology

    Article Title: Metabolic adaptation of a methanogen to a ferruginous environment associated with intracellular Fe- and S-rich nanoparticles

    doi: 10.3389/fmicb.2026.1967823

    Figure Lengend Snippet: X-ray diffraction patterns of synthesized mackinawite.

    Article Snippet: The XRD was used to analyze the mineralogy of the synthetic mackinawite with a Rigaku Smart lab X-ray powder diffractometer (Rigaku, Japan) employing Cu Kα radiation at 40 kV and 200 mA.

    Techniques: Synthesized

    Transmission electron microscopy (TEM), high-resolution TEM (HRTEM), fast Fourier transform (FFT), and energy-dispersive X-ray spectroscopy (EDS) analyses of mackinawite under different Fe 2+ and HS − conditions. The TEM images in the top row show (A) 50 µM FeS Mack alone, (B) 50 µM FeS Mack supplemented with 250 µM Fe 2+ , and (C) 50 µM FeS Mack supplemented with 250 µM HS − . The corresponding HRTEM images, FFT patterns, and EDS spectra are shown below each TEM image in the same column. TEM images show the general morphology, while HRTEM images reveal lattice fringes corresponding to specific crystallographic planes. Together, these analyses support the identification of the material as nanocrystalline mackinawite.

    Journal: Frontiers in Microbiology

    Article Title: Metabolic adaptation of a methanogen to a ferruginous environment associated with intracellular Fe- and S-rich nanoparticles

    doi: 10.3389/fmicb.2026.1967823

    Figure Lengend Snippet: Transmission electron microscopy (TEM), high-resolution TEM (HRTEM), fast Fourier transform (FFT), and energy-dispersive X-ray spectroscopy (EDS) analyses of mackinawite under different Fe 2+ and HS − conditions. The TEM images in the top row show (A) 50 µM FeS Mack alone, (B) 50 µM FeS Mack supplemented with 250 µM Fe 2+ , and (C) 50 µM FeS Mack supplemented with 250 µM HS − . The corresponding HRTEM images, FFT patterns, and EDS spectra are shown below each TEM image in the same column. TEM images show the general morphology, while HRTEM images reveal lattice fringes corresponding to specific crystallographic planes. Together, these analyses support the identification of the material as nanocrystalline mackinawite.

    Article Snippet: The XRD was used to analyze the mineralogy of the synthetic mackinawite with a Rigaku Smart lab X-ray powder diffractometer (Rigaku, Japan) employing Cu Kα radiation at 40 kV and 200 mA.

    Techniques: Transmission Assay, Electron Microscopy, High-Resolution TEM, Energy Dispersive X-Ray, Spectroscopy, Morphology